See graph to determine the required vertical rise

V

T

for the

required horizontal run

H

T

For vent confi gurations requiring more than two 90° elbows
the following formulas apply:

Formula 1: H

T

< V

T

Formula 2: H

T

+ V

T

< 35 feet

Example 4:

FIGURE 12

The shaded area within the lines represents acceptable
values for H

T

and V

T

.

REAR EXIT / HORIZONTAL TERMINATION

Simple venting confi guration

(only two 90° elbows)

FIGURE 13

H

3

90°

90°

90°

V

2

H

1

V

1

H

2

V

1

= 9 ft

V

2

= 6 ft

V

T

=

V

1

+

V

2

= 9 + 6 = 15 ft

H

1

=

3

ft

H

2

=

2

ft

H

3

=

1.5

ft

H

R

=

H

1

+

H

2

+

H

3

= 3 + 2 + 1.5 = 6.5 ft

H

O

= .03(four 90° elbows - 90°)

= .03(90 + 90 + 90 + 90 - 90) = 8.1 ft

H

T

=

H

R

+

H

O

= 6.5 + 8.1 = 14.6 ft

H

T

+ V

T

= 14.6 + 15 = 29.6 ft

Formula 1:

H

T

< V

T

14.6 < 15

Formula 2:

H

T

+ V

T

< 35 feet

29.6 < 35

Since both formulas are met, this vent confi guration is
acceptable.