Top exit / horizontal termination, 90° h, Definitions elbow vent length values – Napoleon Fireplaces Vittoria GD19P User Manual
Page 10
![background image](/manuals/193924/10/background.png)
10
W415-0612 / C / 01.25.08
90°
90°
90°
H
1
V
2
H
2
V
1
nfi guration (only one 90° elbow)
Simple venting confi guration
(only one 90° elbow)
See graph to determine the required vertical rise
V
T
for the
required horizontal run
H
T
.
For vent confi gurations requiring more than one 90° elbow,
the following formulas apply:
Formula 1: H
T
< V
T
Formula 2: H
T
+ V
T
< 35 feet
Example 1:
V
1
= 3 ft
V
2
= 8 ft
V
T
=
V
1
+
V
2
= 3 + 8 = 11 ft
H
1
= 2.5
ft
H
2
= 2
ft
H
R
=
H
1
+
H
2
= 2.5 + 2 = 4.5 ft
H
O
= .03(three 90° elbows - 90°) = .03(270° - 90°) = 5.4
ft
H
T
=
H
R
+
H
O
= 4.5 + 5.4 = 9.9 ft
H
T
+ V
T
= 9.9 + 11 = 20.9 ft
Formula 1:
H
T
< V
T
9.9 < 11
Formula 2:
H
T
+ V
T
< 35 feet
20.9 < 35
Since both formulas are met, this vent confi guration is
acceptable.
FIGURE 8
The shaded area within the lines represents acceptable
values for H
T
and V
T
.
For the following symbols used in the venting calculations
and examples are:
> - greater than
> - equal to or greater than
< - less than
< - equal to or less than
H
T
- total of both horizontal vent lengths (
H
R
) and offsets
(
H
O
) in feet
H
R
- combined horizontal vent lengths in feet
H
O
- offset factor: .03(total degrees of offset - 90°
*) in
feet
V
T
- combined vertical vent lengths in feet
feet
inches
1°
0.03
0.5
15°
0.45
6.0
30°
0.9
11.0
45°
1.35
16.0
90°
*
2.7
32.0
* the fi rst 90° offset has a zero value and is shown in the
formula as -90°
DEFINITIONS
ELBOW VENT LENGTH VALUES
TOP EXIT / HORIZONTAL TERMINATION
FIGURE 7
0
2.5
5
7.5
10
12.5
15
35
10
20
30
17.5
20
33.3
17.5
.5
(H
T
) < (V
T
)
REQUIRED
VERTICAL
RISE IN
FEET
V
T
HORIZONTAL VENT RUN PLUS OFFSET IN FEET
H
T