Specifications

© National Instruments Corporation

A-3

NI SPEEDY-33 User Manual

Physical

PCB only

Dimensions ..................................... 8.89 cm

× 12.7 cm × 1.91 cm

(3.5 in.

× 5 in. × 0.75 in.)

Weight............................................. 87.9 g (3.1 oz)

With enclosure

Dimensions ..................................... 11.1 cm

× 14.5 cm × 3.9 cm

(4.4 in.

× 5.7 in. × 1.5 in.)

Weight............................................. 380 g (12.8 oz)

USB connector ....................................... Type B USB port, conforms to

USB Specification 1.1

Connector ............................................... Standard mini stereo jack

I/O connectors

J1, J2, J5, J12 .................................. 0.10 in.

× 0.10 in. × 0.23 in.

in 1

× 3 rows

J4 ..................................................... 0.10 in.

× 0.10 in. × 0.23 in.

in 2

× 5 rows

J6, J11 ............................................. 0.10 in.

× 0.10 in. × 0.23 in.

in 2

× 10 rows

Environmental

The NI SPEEDY-33 device is intended for indoor use only.

Operating temperature............................ 0 to 55 °C

Storage temperature ............................... –20 to 70 °C

Humidity ................................................ 10 to 90% RH, noncondensing

Maximum altitude .................................. 2,000 m

Pollution Degree .................................... 2

If you need to clean the module, use a soft, nonmetallic brush. Make sure
that the module is completely dry and free from contaminants before