Physical

Dimensions
(not including connectors) .................... 16.0 by 10.0 cm (6.3 by 3.9 in.)

I/O connectors

NI PXI-7831R................................. Three 68-pin female high-density

VHDCI type

Maximum Working Voltage

Maximum working voltage refers to the signal voltage plus the
common-mode voltage.

Channel-to-earth..................................... ±12 V, Installation Category I

Channel-to-channel ................................ ±24 V, Installation Category I

Environmental

Operating temperature............................ – 40 to 70

°C

Storage temperature ............................... –55 to 85 °C

Humidity ................................................ 10 to 90% RH, noncondensing

Maximum altitude .................................. 2,000 meters

Pollution Degree (indoor use only) ........ 2

Safety

The NI PXI-7831R devices meet the requirements of the following
standards for safety and electrical equipment for measurement, control, and
laboratory use:

IEC 61010-1, EN 61010-1

UL 3111-1

CAN/CSA C22.2 No. 1010.1

Note

For UL and other safety certifications, refer to the product label or to

ni.com

.