National Instruments NI WAP-3711 User Manual
Page 7
NI WAP-3701/3711 User’s Manual
Introduction
1-3
802.11g:
10% PER@6Mbps≤-88dBm,
10% PER@9Mbps≤-87dBm
10% PER@12Mbps≤-84dBm,
10% PER@18Mbps≤-82dBm
10% PER@24Mbps≤-79dBm,
10% PER@36Mbps≤-75dBm
10% PER@48Mbps≤-69dBm,
10% PER@54Mbps≤-68dBm
Software Features
Protocols
HTTP, DHCP, TCP/IP, RADIUS, DNS, NetBIOS, NetBEUI,
AppleTalk, and IPX/SPX
Configuration Web-based
management
Client OS Support
Windows 95/98/2000/ME/NT/XP, Unix, and Macintosh
Interface
Antenna
2dBi diversity antenna with an R-SMA connector
RJ45 port
10/100BaseT(X) auto negotiation speed
LED Indicators
PWR1, PWR2, WLAN (Link/ACT), LAN (Link/ACT)
Power
Input Voltage
12 to 45 VDC; Redundant dual DC power inputs or Power over
Ethernet (PoE, power on RJ45 pins 4, 5 for power + and pins 7, 8
for power -)
Input Current (@24V)
0.3A
Connection
Removable Terminal Block
Overload Current Protection
1.6A
Reverse Polarity Protection
Present
Mechanical
Casing
IP30 protection, metal case
Installation
DIN-Rail or panel mounting
Environment
Operating Temperature
0 to 60°C (32 to 140°F)
Storage Temperature
-20 to 70°C (-4 to 158°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Regulatory Approvals
Safety
UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, TUV
Hazardous Location
UL/cUL Class I, Division 2, Groups A, B, C, and D
Emissions FCC,
CE,
SRRC