beautypg.com

Security lock – NEC RS-232C User Manual

Page 39

background image

(39/50)

SOH-'0'-Monitor ID-'0'-'A'-'0'-'6'

STX-'C'-'2'-'1'-'7'-ETX

BCC

CR


Header

SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get Model Name.

Ex.) If Monitor ID is '1', specify 'A'.

'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'6'(30h, 36h): Message length

Message

STX (02h): Start of Message

'C'-'2'-'1'-'7' (43h, 32h,

31h,

37h): Model Name command

ETX (03h): End of Message


Check code

BCC: Block Check Code
Refer to the section 4.5

“Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet


2) The monitor replies the model name data to the controller.

Header

Message

Check code

Delimiter

SOH-'0'-'0'-Monitor ID-'B'-N-N

STX-'C'-'3'-'1'-'7'-Data(0) -Data(1)

—---

-Data(n)-ETX

BCC

CR


Header

SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.

Ex.)

When this byte is set to 'A', the replying Monitor ID is '1'.

'B' (42h): Message type is "Command reply".
N-N: Message length

Note.) The maximum data length that can be returned from the monitor at a time is

32bytes.

Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).


Message

STX (02h): Start of Message

'C'-'3'-'1'-'7' (43h, 33h, 31h, 37h): Model Name reply Command
Data(0) -Data(1)----Data(n):Model name

These data are encoded to ASCII characters strings.

ETX (03h): End of Message


Check code

BCC: Block Check Code
Refer to the section 4.5

“Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

13. Security Lock

13.1 Security Lock Control

This command sets the condition of security lock function to "LOCK" or "UNLOCK".

If security pass codes 1st to 4th are matched with monitor resisted pass codes, then this
command is executed, and reply no error status and a new condition.
If codes aren't matched with them then setting isn't changed, and reply error status and
a current condition.
If the monitor receives this command while waiting for Pass codes inputs, then it only
checks Pass cords (and releases image muting if Pass codes are OK) and doesn't apply "EN"
parameter.