Check code

BCC: Block Check Code
Refer to the section 4.5

“Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet





***Following command also can be used for to keep backward compatibility, in order to
read the setting of the Schedule.


1) The controller requests the monitor to read Schedule.

Header

Message

Check code

Delimiter

SOH-'0'-Monitor ID-'0'-'A'-'0'-'8'

STX-'C'-'2'-'1'-'3'-PG-ETX

BCC

CR

Header

SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to get status.

Ex.) If Monitor ID is '1', specify 'A'.

'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length

Message

STX (02h): Start of Message
'C'-'2'-'1'-'3' (43h, 32h, 31h, 33h): Schedule read request command.
PG: Program No.

The data must be ASCII characters strings.

ETX (03h): End of Message


Check code

BCC: Block Check Code

Refer to the section 4.5

“Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

2) The monitor replies Schedule to the controller.

Header

Message

Check code

Delimiter

SOH-'0'-'0'-Monitor ID-'B'-'1'-'6'

STX-'C'-'3'-'1'-'3'-PG-ON HOUR-ON MIN-
OFF HOUR-OFF MIN-INPUT-WD-FL-ETX

BCC

CR

Header

SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.

Ex.)

When this byte is set to 'A', the replying Monitor ID is '1'.

'B' (42h): Message type is "Command reply".
'1'-'6'(31h, 36h): Message length

Message

STX (02h): Start of Message
'C'-'3'-'1'-'3' (43h, 33h, 31h, 33h): Schedule read reply command
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL: Schedule data

PG: Program No.

'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7

ON_HOUR: Turn on time (hour)