SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get status.

Ex.) If Monitor ID is '1', specify 'A'.

'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'4'(30h, 34h): Message length


Message

STX (02h): Start of Message

'B'-'1' (42h, 31h): Self-diagnosis command
ETX (03h): End of Message


Check code

BCC: Block Check Code
Refer to the section 4.5

“Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

2) The monitor replies a result of the self-diagnosis.

Header

Message

Check code

Delimiter

SOH-'0'-'0'-Monitor ID-'B'-N-N

STX-'A'-'1'-
ST(0)-ST(1) --------ST(n)-ETX

BCC

CR

Header

SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.

Ex.)

When this byte is set to 'A', the replying Monitor ID is '1'.

'B' (42h): Message type is "Command reply".
N-N: Message length

Note.) The maximum data length that can be written to the monitor at a time is 32bytes.
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (34h and 30h).


Message

STX (02h): Start of Message

'A'-'1' (41h, 31h): Application Test Report reply command
ST: Result of self-tests

'0'-'0'(30h, 30h):00: Normal
'7'-'0'(37h, 30h):70: Standby-power +3.3V abnormality
'7'-'1'(37h, 31h):71: Standby-power +5V abnormality
'7'-'2'(37h, 32h):72: Panel-power +12V abnormality
'7'-'3'(37h, 33h):73: Main-power +2.5V abnormality
'7'-'4'(37h, 34h):74: Main-power +1.8V abnormality
'7'-'5'(37h, 35h):75: Main-power +5V abnormality
'7'-'6'(37h, 36h):76: Sub-power +3.3V abnormality
'7'-'7'(37h, 37h):77: Main-power +3.3V abnormality
'8'-'0'(38h, 30h):80: Cooling fan-1 abnormality
'8'-'1'(38h, 31h):81: Cooling fan-2 abnormality
('8'-'2'(38h, 32h):82: Cooling fan-3 abnormality)
'9'-'0'(39h, 30h):90: Inverter abnormality
'A'-'0'(41h, 30h):A0: Temperature abnormality

– shutdown

'A'-'1'(41h, 31h):A1: Temperature abnormality

– half brightness


ETX (03h): End of Message


Check code

BCC: Block Check Code
Refer to the section 4.5

“Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet