Place the jumpers you just disconnected in the 4-wire position

shown in the next figure.

Suspend the master unit from the rough-in by looping the support

wire assembly (thick green wire) over the hook at the top of the

rough-in. Be careful not to damage the wall surface.

Plug in the modular chime plug to the 4 pin connector labeled as

CHIME on the NM100 master unit as shown in the next figure.

If the NM100 system has more than 9 remote stations, some remote

selector switches will control two remote stations. Connect each

Green wire (except patio/outdoor remote Green) to a single green

terminal on the master. Each numbered Green terminal corresponds

to a remote station selector switch. Note: No more than 2 Green

wires can be connected to any Green terminal and not to exceed 15

speakers for the 4-wire or 13 speakers for the 3-wire system. This

limitation does include remote controls and volume controls but not

door stations. The station location can be marked on the inside of

the door access panel on the left side of the NM100 master.
Connect the green wire(s) from the outdoor remote station(s) to the

Patio green terminal. Connect the outdoor remote Black wire(s) to

the patio Black terminal. Note: Only two outdoor remote stations

can be connected to the patio terminals. Connect the Red wire with

the other Red wires to the Red terminal. Connect the White wire

with the other White wires to the White terminal. Refer to the figure

shown below for wire placement.

Connect the red and black wires of the door station cables (NW4S)

to the red and black door station terminals on the NM100 master

as shown in the next figure. When using the NW4S shielded

wire, insulate the bare wires using some of the jacket material to

prevent shorting to the circuit board. Connect this wire to terminal

labeled shield. Connect all orange wires from the door stations to

the common terminal on the NA3003C or NA3008C chime module.

Connect each yellow wire to a note sleection terminal. (Do not

connect more than one yellow wire per note terminal).

iNstalliNg tHe Nm100
The NM100 ships configured for a 3-wire retrofit system. If you are

replacing a 4-wire system you must change the jumper setup on the

NM100 master. The jumper change must be completed before any

cables are connected. To change the jumpers just pull them off the

existing connections shown in the next figure.