replaciNg tHe room statioNs
The remote and door stations use the existing wire and station

rough-in mounting frames or boxes. To replace the station, first

remove the old station. Leave the existing remote or door station

rough-ins in place.
After removing the remote station verify the integrity of the wire run.

Then install the mounting plate from the NF300RWH frame. Align

the plate on the wall either vertically or horizontally so that the screw

holes line up with those on the rough-in or box. Use a level to make

sure the plate is level. There are several screw hole locations on the

mounting plate so it can attach to many rough-in designs. Mount the

plate to the wall using the screws provided.

Nm100

coNNectioN

NutoNe

iWa3 cable

Wire fuNctioN

Black

Blue Stripe or

Outside Copper Wire

Intercom Mic
Audio Input & Control

Red

Center Wire

Ground

Green

Red Stripe or Outside

Silver Wire

Speaker
Output/Monitor
Mic Input

Four-wire Installations

Connect the remote station to the existing wiring using the diagrams

above. Place the remote station through the NF300RWH plastic

mounting frame. Position the frame either vertically or horizontally

depending on the remote station replaced. Place the remote station

into the rough-in ring and align the frame with the remote station.

Three-wire Installations

Next connect the wires to the retrofit remote station. Match the wire

colors to the corresponding screw locations on the NRS103WH

or NRS104WH remote stations. Please make sure to use only

NRS103WH remote stations in a 3-wire installation and NRS104WH

remote stations in a 4-wire installation. All 6-wire installations use

the NRS200WH remote stations. Please refer to appendix A for a

diagram of which NuTone and M&S systems map to the 3, 4 or 6-

wire (requires NM200 master) configurations. Refer to the following

two charts for the NM100 wiring diagram:

For the NWH300C Master Station and CD combination rough-in,

have a qualified electrician loop a power wire from the NA200TA

transformer enclosure to the NA300TA transformer enclosure

following the same procedure described previously and shown in

the next figure.

NM100

CONNECTION

NUTONE 4

CONDUCTOR

WITH GRAY

JACKET

M&S 4

CONDUCTOR

CABLE

WITH GRAY

JACKET

WIRE

FUNCTION

White

Blue Stripe

Wire

Silver Outside

Gray Wire

Intercom Mic

Audio Input

Black

Gray/Copper

Wire

Next Copper

Outside Gray

Wire

Intercom

Control

Red

Gray/Silver

Wire

Next Copper

Outside Gray

Wire

Ground

Green

Red Stripe

Wire

Outside

Copper

Outside Red

Stripe Wire

Speaker

Output/Monitor

Mic Input

NM100

CONNECTION

M&S MS4XSC

CABLE

NUTONE

NW4S CABLE

WIRE

FUNCTION

White

White

Red

Intercom Mic

Audio Input

Black

Black

Black

Intercom

Control

Red

Red

Orange

Ground

Green

Green

Yellow

Speaker

Output/Monitor

Mic Input