Power requirement, Physical, Environment – National Instruments SCXI-1190/1191 User Manual
Page 31: Certifications and compliances ce mark compliance
![background image](/manuals/191464/31/background.png)
Appendix A
Specifications for SCXI-1190
© National Instruments Corporation
A-3
Caution
Exceeding the maximum switching capability will decrease the expected life of
the SCXI-1190.
Power Requirement
+5 VDC
Maximum (all relays closed) .......... 600 mA
Physical
Dimensions............................................. 17.30 by 19.56 by 3.02 cm
(6.81 by 7.70 by 1.19 in.)
I/O connector.......................................... 5 SMB female per bank
Environment
Operating temperature ..........................0 to 50
°
C
Storage temperature..............................–20 to 70
°
C
Relative humidity ................................... 5% to 85% noncondensing
Electromagnetic compatibility
(EMC) emissions ............................ Refer to the document supplied
with the chassis for compliance to
relevant directives.
EMI ................................................. FCC Class A compliant
Certifications and Compliances
CE Mark Compliance
See the Declaration of Conformity sheet accompanying product.