Specifications – National Instruments Terminal Block NI TB-2706 User Manual
Page 6

NI TB-2706 Installation Guide
6
ni.com
Specifications
These specifications are typical at 25 °C unless otherwise specified.
Input/Output
Caution
The TB-2706 is not designed for input voltages greater than 42 V
pk
/60 VDC.
Refer to the documentation for your M Series or PXI-6143 device to determine the input/output
specifications for your application.
Physical
Dimensions ............................................................10.7
Ч 8.6 Ч 2.0 cm (4.2 Ч 3.4 Ч 0.8 in.)
Dimension from face of PXI/PXIe card.................8.6 cm (3.4 in.)
Weight ....................................................................289 g (10.2 oz)
I/O connector .........................................................One 68-position male VHDCI connector
Screw terminals
Number ..........................................................70
Type................................................................Angled entry, 3.81 mm pitch
Wire gauge .............................................................26–16 AWG
Environment
Operating temperature ...........................................0 to 55 °C
Storage temperature ...............................................–20 to 70 °C
Relative humidity...................................................10 to 90% noncondensing
Pollution Degree (indoor use only)........................2
Altitude ..................................................................2,000 m
Safety
This product is designed to meet the requirements of the following standards of safety for electrical
equipment for measurement, control, and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
Note
For UL and other safety certifications, refer to the product label or visit
ni.com/
certification
, search by model number or product line, and click the appropriate link in the
Certification column.
Electromagnetic Compatibility
This product is designed to meet the requirements of the following standards of EMC for electrical
equipment for measurement, control, and laboratory use:
•
EN 61326 EMC requirements; Minimum Immunity
•
EN 55011 Emissions; Group 1, Class A
•
CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
Note