NI 9264 Operating Instructions and Specifications

protection. Refer to Figure 4 for an illustration of the output
circuitry for one channel of the NI 9264.

Figure 4. Output Circuitry for One Channel of the NI 9264

When the module powers on, the channels output the startup
voltage. Refer to the

Specifications

section for more information

about startup voltage. Refer to the software help for information
about configuring startup output states in software.

AO

COM

NI 9264

Amp

Isolated

DAC

Overvoltage/

Short-Circuit

Protection