Storage environment, Shock and vibration (for ni pxi-783 x r only) – National Instruments NI 783xR User Manual
Page 54

Appendix A
Specifications
© National Instruments Corporation
A-9
Relative humidity range ......................... 10% to 90%, noncondensing,
tested in accordance with
IEC-60068-2-56
Altitude................................................... 2,000 m at 25
°C ambient
temperature
Storage Environment
Ambient temperature range.................... –20
°C to 70 °C tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2
Relative humidity range ......................... 5% to 95%, noncondensing,
tested in accordance with
IEC-60068-2-56
Note
Clean the device with a soft, non-metallic brush. Make sure that the device is
completely dry and free from contaminants before returning it to service.
Shock and Vibration (for NI PXI-783xR Only)
Operational Shock.................................. 30 g peak, half-sine, 11 ms pulse
Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.
Random Vibration
Operating ........................................ 5 Hz to 500 Hz, 0.3 g
rms
Nonoperating .................................. 5 Hz to 500 Hz, 2.4 g
rms
Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.