2.3 GENERAL
INFORMATION
GDS28
GS28
NG
LP
NG
LP
Altitude (FT)
0-4,500
0-4500
0-4500
0-4500
Max. Input (BTU/HR)
30,000
26,000
30,000
26,000
Max. Output (BTU/HR)
25,500
22,360
24,600
21,600
Max. Steady State
Effi ciency (w/the fan
on)
85%
86%
82%
83%
Max. A.F.U.E.
76%
77%
Min. Inlet Gas Supply
Pressure
4.5" Water Column
11" Water Column
4.5" Water Column 11" Water Column
Max. Inlet Gas Supply
Pressure
7" Water Column
13" Water Column
7" Water Column
13" Water Column
Manifold Pressure
(Under Flow
Conditions)
3.5" Water Column
10" Water Column
3.5" Water Column 10" Water Column
When the appliance is installed at elevations above 4,500 ft, and in the absence of specifi c recommendations from
the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000 ft.
Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in propane.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance may be installed in an aftermarket permanently located, manufactured mobile home, where not
prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
This appliance is approved for bedroom and bed-sitting room installations.
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!