beautypg.com

Napoleon Fireplaces GDS28P User Manual

Page 7

background image

7

W415-0153 / B / 06.10.10

2.3 GENERAL

INFORMATION

GDS28

GS28

NG

LP

NG

LP

Altitude (FT)

0-4,500

0-4500

0-4500

0-4500

Max. Input (BTU/HR)

30,000

26,000

30,000

26,000

Max. Output (BTU/HR)

25,500

22,360

24,600

21,600

Max. Steady State
Effi ciency (w/the fan
on)

85%

86%

82%

83%

Max. A.F.U.E.

76%

77%

Min. Inlet Gas Supply
Pressure

4.5" Water Column

11" Water Column

4.5" Water Column 11" Water Column

Max. Inlet Gas Supply
Pressure

7" Water Column

13" Water Column

7" Water Column

13" Water Column

Manifold Pressure
(Under Flow
Conditions)

3.5" Water Column

10" Water Column

3.5" Water Column 10" Water Column

When the appliance is installed at elevations above 4,500 ft, and in the absence of specifi c recommendations from
the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000 ft.

Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in propane.

Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.

This appliance may be installed in an aftermarket permanently located, manufactured mobile home, where not
prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.

This appliance is approved for bedroom and bed-sitting room installations.

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!