6.1 OPERATING/LIGHTING

INSTRUCTIONS

The on-off switch is located on the back of the unit at the top left corner on models GDS28 and GS28.

When lit for the fi rst time, the appliance will emit a slight odour for a few hours. This is a normal temporary
condition caused by the "burn-in" of paints and lubricants used in the manufacturing process and will not occur
again. Simply open a window to suffi ciently ventilate the room. After extended periods of non-operation such as
following a vacation or a warm weather season, the appliance may emit a slight odour for a few hours. This is
caused by dust particles in the heat exchanger burning off. Open a window to suffi ciently ventilate the room.

OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions
exactly, a fi re or explosion may result causing
property damage, personal injury or loss of life.

A.

This fi replace is equipped with a pilot which must be lit

by hand while following these instructions exactly.

B.

Before operating smell all around the fi replace area for

gas and next to the fl oor because some gas is heavier
than air and will settle on the fl oor.

C.

Use only your hand to turn the gas control knob /

manual shut-off knob. Never use tools. If the knob will
not turn by hand, do not try to repair it. Call a qualifi ed
service technician. Force or attempted repair may
result in a fi re or explosion.

D.

Do not use this fi replace if any part has been under

water. Immediately call a qualifi ed service technician
to inspect the fi replace and replace any part of the
control system and any gas control which has been
under water.

WHAT TO DO IF YOU SMELL GAS:

Turn off all gas to the fi replace.

• Open

windows.

Do not try to light any appliance.

Do not touch any electric switch; do not use any
phone in your building.

Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fi re
department.

LIGHTING INSTRUCTIONS

WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the
thermocouple has cooled. Allow approximately 60 seconds for the thermocouple to cool.
When lighting and re-lighting, the gas knob cannot be turned from PILOT to OFF unless the knob is depressed.

1.

STOP! Read the safety information on the operating

label.
2.

Turn off all electric power to the fi replace.

3.

Turn the gas knob clockwise

to off.

4.

Wait fi ve (5) minutes to clear out any gas. If you smell

gas including near the fl oor, Stop! Follow "B" on the
operating label. If you don't smell gas go to the next step.
5.

Find pilot located in front of back log.

6.

Turn gas knob counter-clockwise

to pilot.

7.

Depress and hold gas knob while lighting the pilot with

the push button ignitor. Keep knob fully depressed for
one minute, then release. If pilot does not continue to
burn repeat steps 3 through 6.
8.

With pilot lit, turn the gas knob counter-clockwise

to on.
9.

If equipped with remote on-off switch, main burner

may not come on when you turn the valve to on. Remote
switch must be in the on position to ignite burner.
10.

Turn on all electric power to the fi replace.

TO TURN OFF GAS

1.

Turn off all electric power to the fi replace if service is to

be performed.

2.

Push in gas control knob slightly and turn clockwise

to off. Do not force.

PILOT

BURNER

THERMOCOUPLE

THERMOPILE

P

I

PILOT

N

O

L

O

T

H I

LO

FF O

GAS KNOB
AT OFF