beautypg.com

Nuvo NV-E6DMS User Manual

Page 28

background image

Once it is SET by one of these commands:
a. It will remain set until power is cycled on the unit.
b. Non-address DIP switch changes on a connected KEYPAD connected to this zone will be ignored.

If override state is "0", this response is also issued whenever non-address KEYPAD DIP switches are changed.

*********************************************************************************
COMMAND:

*ZxxON – Turn zone xx ON.

RESPONSE:

Same response as for *ZxxCONSR

*********************************************************************************
COMMAND:

*ZxxOFF – Turn zone xx OFF.

RESPONSE:

Same response as for *ZxxCONSR

*********************************************************************************
COMMAND:

*ALLOFF – Turn ALL zones OFF.

RESPONSE:

#ALLOFF

This RESPONSE is also issued when ALL OFF is pressed on any KEYPAD.
*********************************************************************************
COMMAND:

*ALLV+ – Ramp ALL zones UP at a 10 dB/second rate in 1 dB steps.

RESPONSE:

#ALLV+

The ramp action will be cancelled when all zones reach MAXIMUM volume, or when an *ALLHLD Command is received. Note that to stop the
ramp with this command before maximum volume, one reference zone must be periodically polled with a *ZxxCONSR Command to determine
when the desired volume point has been reached. Note that ramps in different zones may start at different levels and will all ramp at the same
rate.

*********************************************************************************
COMMAND:

*ALLV- – Ramp ALL zones DOWN at a 10 dB/second rate in 1 dB steps.

RESPONSE:

#ALLV-

The ramp action will be cancelled when all zones reach MINIMUM (OFF) volume, or when an *ALLHLD Command is received. Note that to
stop the ramp with this command before the minimum volume, one reference zone must be periodically polled with a *ZxxCONSR Command
to determine when the desired volume point has been reached. Note that ramps in different zones may start at different levels and will all ramp
at the same rate.

*********************************************************************************
COMMAND:

*ALLHLD – Stops ramp action initiated by *ALLV+ Or *ALLV-

RESPONSE:

#ALLHLD-

This results in a HOLD of the level at time of command receipt.

*********************************************************************************
COMMAND:

*ALLMON – ALL MUTE ON.

RESPONSE:

# ALLMON

*********************************************************************************
COMMAND:

*ALLMOFF – ALL MUTE OFF.

RESPONSE:

#ALLMOFF

********************************************************************************
COMMAND:

*ZxxSRCp – Switch zone xx to SOURCE p ( 1 to 6).

RESPONSE:

Same response as for *ZxxCONSR

*********************************************************************************

28