DISPLAY COUNTER VALUES

The internal counters are used to track the number of kilometers of media that has been

processed through the printer, the number of labels cut and/or the number of label

dispensed. These values can be used to track component life for service and

maintenance functions. The current counter settings are displayed on the

Factory/Service mode Test Label. To print the Factroy/Service Test Label, the

following procedure must be used:

1. Turn the printer OFF and place DSW2-4 in the ON position.

2. Open the print head by releasing the Head Latch.

3. While simultaneously pressing the LINE and FEED keys, turn the printer

ON.

4. Close and latch the print head.

5. The LCD panel should read:

6. Place DSW2-4 in the OFF position.

7. The LCD panel should indicate that the printer is in the FACTORY MODE.

8. Press the FEED key and the display will advance to the COUNTER CLEAR

message screen. Make sure that the NONE selection is displayed on the

bottom line. If it is not, press the LINE key once until ALL is displayed.

9. Press the FEED key to initiate the Test Label print mode. Then press the

LINE key to begin printing Test Labels. The printer will print Test Labels

continuously until the FEED key is pressed again, which pauses the printer.

Test Labels will again start printing as soon as the FEED key is pressed

again.

WARNING: The Test Label is designed to print on a full width label. If smaller

labels are used, the print head may be damaged if more than one label is printed.

10. The counter readings and ROM version are printed on the label along with

other pertinent information.

11. Turn the unit OFF and reset the DIP switches to the proper operating

positions before powering the printer back ON.

37

Section 3. Configuration

FACTORY MODE

COUNTER CLEAR
NONE

MAINTENANCE MODE

DIPSW2-4 ON->OFF