beautypg.com

Connection of a remote control box (rcb), Fuse – Panasonic AW-E600 User Manual

Page 18

background image

-16-

VIDEO OUT

G/L IN

I/F REMOTE

OPTION CARD

IRIS

DC12V IN

MENU

ITEM/AWC

YES/ABC

NO/BAR

ALL

1

2

USER SET

ON

POWER

OFF

POWER

O I

FUSE(POWER)

FUSE

FUSE

AC Adaptor

AW-

PS505

CONNECTION OF A REMOTE CONTROL BOX (RCB)

The RCB (WV-CB700A) and the camera must be con-
nected with the optional RCB cable AW-CA50T10.

1. Turn RCB power off before connecting cables.
2. Connect the 50-pin connector of the RCB cable to

I/F REMOTE connector of the camera. The 10-pin
connector must be connected to the RCB.

3. Turn RCB power on and the camera can be con-

trolled remotely by the RCB.

Notes:

• The monitor output signals of the RCB attenuate

and deteriorate with cable length. It is recommend-
ed that the signals from the monitor output be used
for monitoring purposes only.

• No gen-lock signal is available from the RCB.

AC Adaptor
AW-PS505

Video signal IN

RCB WV-CB700A

1. Connect this to a DC 12 V class 2 power supply

only.

2. To prevent fire or shock, the UL listed wire VW-1,

style 1007 should be used as for the cable for DC
12 V Input Connector.

Cautions

RCB Cable AW-CA50T10 (3 m)

MONITOR OUT

DC Power Cable
AW-CA4T1

RCB