Table 8. Weights and Dimensions
UPS
Extended Battery Module (EBM)
Dimensions
(WxDxH)
44.2 x 68.3 x 21.8 cm
17.4” x 26.9” x 8.6” (5U)
44.2 x 68.3 x 13 cm
17.4” x 26.9” x 5.1” (3U)
Weights
UPS Chassis: 35 kg (77 lb)
Internal Battery Trays (2): 27.4 kg (60.5 lb) each
Total UPS Weight: 89.8 kg (198 lb)
69.9 kg (154 lb)
Table 9. Battery
Configuration
(20) 12V, 7.2 Ah internal batteries
EBM Configuration
PW9125 240 EBM: (20) 12V, 9 Ah
Type
Sealed, maintenance-free, valve-regulated, lead-acid
Charging
Internal battery: less than 2 hours to 80% usable capacity at nominal line voltage after
full load discharge
External battery: no more than 15x discharge time to 90% usable capacity at nominal
line voltage after full load discharge
Monitoring
Advanced monitoring for earlier failure detection and warning
Table 10. Battery Runtimes (in Minutes)
Load
UPS Internal
Batteries
1 EBM
2 EBMs
3 EBMs
4 EBMs
6000 VA/4200W
9.7
29.7
52.1
76.3
102
5000 VA/3500W
13.2
37.4
65.3
95.6
127.7
4000 VA/2800W
19.2
49.2
85.8
125.4
167.5
3000 VA/2100W
24.3
70.1
121.9
178.0
237.4
2000 VA/1400W
37.7
107.5
186.2
271.4
361.6