beautypg.com

Dc power rail module, Component slot allocation – Polycom RMX DOC2548A User Manual

Page 35

background image

Polycom RMX 4000 Hardware Guide

1-29

DC Power Rail Module

A DC power rail module includes a power inlet, circuit breaker, EMI filter

and backplane connectors. Power input to the system is fed via a power

rail through backplane into the power supply. Each DC power rail has its

own dedicated power cable. The circuit switch on the rear of the RMX

activates independently any power rail installed on the RMX. An DC

system has two DC rails, one for each power rail. On failure, a DC power

rail is field replaceable and the RMX must be switched OFF from the two

circuit switches and the mains.

Component Slot Allocation

On the RMX™ 4000, components have been assigned dedicated slots as
defined in Table 1-9. Slot numbers are located on both the front and rear

of the RMX™ 4000.

Table 1-9

RMX™ 4000 Slot Numbering

Slot ID/No.

Card/Component

Requirement

1-4

MPM+ Cards

Mandatory: At least 1 MPM+ card is
required. Each media card also requires
either an RTM ISDN or an RTM LAN
card.

5

Fabric Switch
Module (FSM
4000)

Mandatory

6

CPU 2

Not Available (NA)

7

Logo Panel

Not Available (NA)

8

CTNL 4000 unit
(CPU 1)

Mandatory

9-11

AC Power Supply

An RMX with AC power has 3 power
supplies installed. A 3rd power supply is
redundant (n+1).
Note: Not used with DC powered
systems. DC powered systems receive
Direct Current from the power rail .