beautypg.com

5 setting protocol of dome camera – Philips Video Camera User Manual

Page 13

background image

12

13

2.5 Setting Protocol of Dome Camera

If a dome camera is to be installed with a Fastrax keyboard controller, select F2 protocol.
Consult service personnel if a dome camera is installed with device other than a keyboard controller.

Unless Baud rate match, universal protocol will not work.

Figure 13 – Protocol Selection Switches

D11

D12

Camera

S6-3

S6-4

Off

Off

Default cameras (Default)

Off

On

Reserved

On

Off

Reserved

On

On

Reserved

S/W

On

Off

Function

D1

S4-1

Enable

Disable

Alarm

D2

S4-2

PAL

NTSC

NTSC/PAL

D3

S4-3

Endless

D4

S4-4

RS-422

RS-485

RS-422/RS-485

D5

D6

D7

Protocol

S5-1

S5-2

S5-3

Off

Off

Off

Fastrax, Pelco D&P, Dynacolor, Ernitec &

Philips G3 Protocol (Default)

Off

Off

On

Reserved

Off

On

Off

Sensormatic RS-422

Off

On

On

Reserved

On

Off

Off

Vicon Protocol

On

Off

On

Reserved

On

On

Off

Dynacolor

On

On

On

Reserved

D8

D9

D10

Baud Rate

S5-4

S6-1

S6-2

Off

Off

Off

2400 bps

Off

Off

On

4800 bps

Off

On

Off

9600 bps (Default)

Off

On

On

19200 bps

On

Off

Off

38400 bps

On

Off

On

57600 bps

On

On

Off

115200 bps

On

On

On

230400 bps