beautypg.com

Philips Video Camera User Manual

Page 10

background image

10

11

2.2.4 Two Multiplexer with Slave Keyboard Controller (method 2)

Figure 8 - Two Multiplexer with Slave Keyboard Controller (method 2)

Spot output 1 of the first multiplexer to be connected to 16

th

input of the

second multiplexer.
n: User, Spot out of n

th

to be connected to (17-n)

th

camera input of the 2

nd

multiplexer. n

th

spot out of the 2

nd

multiplexer to be connected to the n

th

spot

monitor. Each user will see the picture of the selected camera (1 ~ (31-n)) on
n

th

spot monitor of the Mux 2 by selecting camera

No. + Cam.

Rear

Keyboard controller
Master

Power

24VAC

BNC

1st Main Monitor

BNC

BNC

RS-485 (–) Pin No. 4
RS-485 (+) Pin No. 6

J-Box (Back)

J-Box (Front)

AWG #24

Power

24VAC

Power

24VAC

Spot Monitor

for Master K/B

1st Multiplexer

BNC

2nd Multiplexer

2nd Main Monitor

Spot Monitor

for Slave K/B

Keyboard controller
Slave

Rear