Primera Technology Cyclone C-1000 User Manual
Page 25

Troubleshooting and Maintenance 21
Section 4: Troubleshooting &
Maintenance
A. TROUBLESHOOTING
Generally, when a malfunction or an abnormal condition
occurs, the READY LED will keep blinking and printing and
communication between the host and printer will stop.
After the problems have been solved, press CANCEL to
continue printing.
Problems with media
Blinking Indicators
READY and MEDIA
Possible
Problems
Solutions
Remarks
Missing gap
Check the media
If you use continuous
path
media, check your
Check the
application software
position of
and driver.
label sensor.
You should select
Continuous.
Media out
Supply the media
roll
Media not
Install the media
installed
roll
Media jam
Fix the jam
If everything is OK, perform a label sensor calibration.
510172_r1.qxd 3/21/2001 6:25 PM Page 21