Switchpack Definitions

Manually change configuration options by moving Switchpack S1 DIP switches
on the card. Table 10 lists Switchpack S1 definitions.

Table 10.

Switchpack S1 Definitions

Switch # . . .

Allows you to . . .

Default in Bold

1

Enable or disable Switchpacks S1 and S2.

OFF = Switchpacks Disabled
ON = Switchpacks Enabled

2

Control line termination.

OFF = 120 Ohm
ON = 75 Ohm

3

Select the unit’s primary timing source. Only valid for units configured
as LTU.

OFF = Internal Clock
ON = External Clock

4

Control the unit’s E1 line coding.

OFF = HDB3
ON = AMI

5

Not used

6

Enable CRC-4 monitoring.

OFF = Enable CRC-4
ON = Disable CRC-4 monitoring

7

Control whether Channel 16 contains signaling information or data.

OFF = Channel 16 is used for signaling
ON = Channel 16 is used for data

8

Not used