beautypg.com

Paradyne M/HDSL Standalone Termination Unit Hotwiret 7986 User Manual

Page 12

background image

12

7986-A2-GZ40-00

March 1999

Table 6.

Communication Protocol Options

Node IP Address

Possible Settings: 000.000.000.000223.255.255.255
Default Setting: 000.000.000.000

Specifies the Node IP address.

H

Node IP Address is only available when the standalone unit is configured as an
LTU.

Node Subnet Mask

Possible Settings: 000.000.000.000255.255.255.255
Default Setting: 000.000.000.000

Specifies the Node Subnet Mask.

H

Node Subnet Mask is only available when the standalone unit is configured as an
LTU.

Default Network Destination

Possible Settings: None, COM, DSL
Default Setting: None

Specifies where the default management network is connected. For example, if your
default network is connected to the COM port, select COM as the default management
network destination.

Communication Port IP Address

Possible Settings: 000.000.000.000223.255.255.255
Default Setting: 000.000.000.000

Specifies the unit’s Communication Port IP Address when the unit is configured as a
network communication link.

H

Communication Port IP Address is only used when the Port Use option on the
Communication Port Options menu is set to Net Link. If the COM Port IP address
is not set (000.000.000.000) the node IP address specified by the Node IP Port will
be used.

Communication Port Subnet Mask

Possible Settings: 000.000.000.000255.255.255.255
Default Setting: 000.000.000.000

Specifies the unit’s Communication Port Subnet Mask when the unit is configured as a
network communication link.

H

Communication Port Subnet Mask is only used when the Port Use option on the
Communication Port Options menu is set to Net Link. If the COM Port IP address
is not set (000.000.000.000), the node IP Address will be used.

Communication Port Link Protocol

Possible Settings: PPP, SLIP
Default Setting: PPP

Specifies the unit’s Communication Port link layer protocol when the unit is configured
as a network communication link.

H

Communication Port Link Protocol is only used when the Port Use option on the
Communication Port Options menu is set to Net Link.