beautypg.com

PVI Industries PV500-47C User Manual

Page 6

background image

6

PV500-47C 06/12

 

2

STANDARD FEATURES AND EQUIPMENT

2.1 Performance

 87% thermal efficiency at full fire from 40° to 140°F

 Up to 92% thermal efficiency with modulation

 < 20 ppm NOx

 Ducts direct combustion air up to 100 equivalent feet through 6-inch diameter material (requires UL approved

vent cap, see optional equipment list)

 Vents up to 100 equivalent feet through 6-inch diameter material


2.2 Pressure

Vessel

 AquaPLEX

(unlined duplex alloy)

 Storage tank ASME stamped and National Board registered for 150 psi MAWP

 Nonferrous, removable fittings at all tank connections

 Hand

hole

cleanout

 Fiberglass

insulation

 Steel jacket panels with industrial-grade finish

 Drain

valve


2.3 Heat

Exchanger

 Three-pass, fire tube design
 AquaPLEX

fire tubes


2.4 Codes

And

Standards

 Intertek / ETL listed to US and Canadian safety standards

 Intertek / ETL listed for use with stainless steel Category IV vent material

 Intertek / ETL certified as low-lead compliant

 FM

compliant

 ASHRAE 90.1 compliant


2.5

Burner, Operating Controls & Safeties

 Pre-mix surface burner with self-adjusting, proportionate gas/air ratio

 UL 795 compliant gas train

 Electronic flame safeguard with pre- and post-purge

 Combustion sequence panel lights including lockout

 Programmable electronic operating control with digital temperature readouts,

adjustable to 70°F to 180°F

 Immersion temperature limiting device (high limit control)

 ASME-rated temperature and pressure relief valve

 NEMA-1

control

enclosure

 Terminals for remote on-off

 Flame failure audible alarm and indicating light with remote contacts

 Seamless VFD modulation with 10-1 turndown


2.6

Warranty and Service Policy

(see warranty or service policy for details)

 10-Year tank warranty (PV 627)

 3-Year scale failure warranty (PV 563)

 First-year cost-free service policy (PV 551)

 10-Year

chloride-induced

stress

corrosion cracking warranty (PV 8083)


2.7 Miscellaneous

 Factory authorized startup

 Vent termination cap, 6-inch diameter (larger cap optional)

Factory-equipped for connection to direct inlet air (requires UL listed vent termination cap, see options list)

Condensate “P” trap (provided for field installation)

Direct inlet air filter