Philips Semiconductors

Product data sheet

SCC2691

Universal asynchronous receiver/transmitter (UART)

2006 Aug 04

5

ABSOLUTE MAXIMUM RATINGS

1

SYMBOL

PARAMETER

RATING

UNIT

T

A

Operating ambient temperature range

2

Note 4

°

C

T

STG

Storage temperature range

–65 to +150

°

C

V

CC

Voltage from V

CC

to GND

3

–0.5 to + 7.0

V

V

S

Voltage from any pin to ground

3

–0.5 to V

CC

+10%

V

P

D

Power Dissipation

300

mW

NOTES:
1. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only and

functional operation of the device at these or any other condition above those indicated in the operation section of this specification is not
implied.

2. For operating at elevated temperature, the device must be derated based on +150

°

C maximum junction temperature.

3. This product includes circuitry specifically designed for the protection of its internal devices from damaging effects of excessive static

charge. Nonetheless, it is suggested that conventional precautions be taken to avoid applying any voltages larger than the rated maxima.

4. Parameters are valid over specified temperature range. See Ordering Information table for applicable operating temperature and V

CC

supply

range.

DC ELECTRICAL CHARACTERISTICS

1, 2, 3

SYMBOL

PARAMETER

TEST CONDITIONS

LIMITS

UNIT

SYMBOL

PARAMETER

TEST CONDITIONS

Min

Typ

Max

UNIT

V

IL

V

IH

Input low voltage
Input high voltage

0.8

V

All except X1/CLK
X1/CLK

2

0.8V

CC

V

CC

V
V

V

OL

V

OH

4

Output low voltage
Output high voltage
(except open drain outputs)

I

OL

= 2.4mA

I

OH

= –400

µ

A

2.4

0.4

V

V

I

IL

Input leakage current

V

IN

=

0

to V

CC

–10

10

µ

A

I

LL

Data bus 3-State leakage current

V

O

=

0.4 to V

CC

–10

10

µ

A

I

OD

Open-drain output leakage current

V

O

= 0.4 to V

CC

–10

10

µ

A

I

XIL

X1/CLK low input current

V

IN

=

0, X2 floated

–100

–30

0

µ

A

I

XIH

X1/CLK high input current

V

IN

= V

CC

, X2 floated

0

30

100

µ

A

I

X2L

X2 low output current

V

OUT

=

0, X1/CLK = V

CC

–100

µ

A

I

X2H

X2 high output current

V

OUT

= V

CC

, X1/CLK = 0V

100

µ

A

I

CCA

I

CCD

Power supply current, active

Power down current

5

0

°

C to +70

°

C

–40

°

C to +85

°

C

0.8
1.0

2.0
2.5

500

mA
mA

µ

A

NOTES:

1. Parameters are valid over specified temperature range. See Ordering Information table for applicable operating temperature and V

CC

supply

range.

2. All voltage measurements are referenced to ground (GND). For testing, all input signals swing between 0V and 3.0V with a transition time of

20ns max. For X1/CLK, this swing is between 0.4V and 4.0V. All time measurements are referenced at input voltages of 0.8V and 2V and
output voltages of 0.8V and 2V as appropriate.

3. Typical values are at +25

°

C, typical supply voltages, and typical processing parameters.

4. Test condition for outputs: C

L

= 150pF, except interrupt outputs. Test conditions for interrupt outputs: C

L

= 50pF, R

L

= 2.7k

to V

CC

.

5. For power down current levels in the 1

µ

A region see the UART application note.