Sync Data Ports

Configuration Option

Settings

Default in [Bold]

Slot

ss

9x62: 01, 02
9x65: 01, 02, 03, 04, 05

Port

p

T1 NAM:1, 2
Sync Data APM: 1, 2, 3, 4

Port Status

Enable, [Disable]

Port Type

[E530], V.35, RS449, X.21

Port Base Rate

[Nx64], Nx56

Transmit Clock Source

[Internal], External

Invert Transmit Clock

Enable, [Disable]

Invert Transmit and Received
Data

Enable, [Disable]

Send All Ones on Data Port Not
Ready

Disable, DTR, RTS, [Both]

Action on Network Yellow Alarm

None, [Halt]

Network Initiated Data Channel
Loopback (DCLB)

[Disable], V.54, FT1, Both

Port (DTE) Initiated Loopbacks

[Disable], DTPLB, DCLB, Both

Embedded Data Link

Enable, [Disable]

EDL Management Link

Enable, [Disable]

IP Address

1

[000.000.000.000] – 223.255.255.255, Clear

Subnet Mask

[000.000.000.000] – 255.255.255.255, Clear

Routing Information Protocol

None, [Proprietary]

Near-End Performance Statistics

[Disable], Maintain, Send, Both

Far-End Performance Statistics

[Disable], Maintain

Out of Frame (OOF) Alarm

[Enable], Disable

Excessive Error Rate (EER)
Alarm

[Enable], Disable

Excessive Error Rate Threshold

[10E-4], 10E-5, 10E-6, 10E-7, 10E-8, 10E-9

1

This first byte cannot be set to 0 nor 127. However, the null address of 0.0.0.0 is
valid after performing a Clear.