Paradyne T1 Access Mux 916x User Manual
Page 4
4
Sync Data Ports
Configuration Option
Settings
Default in [Bold]
Slot
ss
9x62: 01, 02
9x65: 01, 02, 03, 04, 05
Port
p
T1 NAM:1, 2
Sync Data APM: 1, 2, 3, 4
Port Status
Enable, [Disable]
Port Type
[E530], V.35, RS449, X.21
Port Base Rate
[Nx64], Nx56
Transmit Clock Source
[Internal], External
Invert Transmit Clock
Enable, [Disable]
Invert Transmit and Received
Data
Enable, [Disable]
Send All Ones on Data Port Not
Ready
Disable, DTR, RTS, [Both]
Action on Network Yellow Alarm
None, [Halt]
Network Initiated Data Channel
Loopback (DCLB)
[Disable], V.54, FT1, Both
Port (DTE) Initiated Loopbacks
[Disable], DTPLB, DCLB, Both
Embedded Data Link
Enable, [Disable]
EDL Management Link
Enable, [Disable]
IP Address
1
[000.000.000.000] – 223.255.255.255, Clear
Subnet Mask
[000.000.000.000] – 255.255.255.255, Clear
Routing Information Protocol
None, [Proprietary]
Near-End Performance Statistics
[Disable], Maintain, Send, Both
Far-End Performance Statistics
[Disable], Maintain
Out of Frame (OOF) Alarm
[Enable], Disable
Excessive Error Rate (EER)
Alarm
[Enable], Disable
Excessive Error Rate Threshold
[10E-4], 10E-5, 10E-6, 10E-7, 10E-8, 10E-9
1
This first byte cannot be set to 0 nor 127. However, the null address of 0.0.0.0 is
valid after performing a Clear.