Table 5. alarm configuration options – Paradyne ACCULINK 3151 CSU User Manual
Page 11
9
Table 4. User Interface Configuration Options (4 of 4)
Option
Comments/Description
Factory 2
Factory 1
5
5
TnDiscTm: (Telnet
Di
t Ti
)
Up
Up
The period of inactivity (1 to
60 minutes) that causes a
TnDiscTm: (Telnet
Disconnect Time)
Down
Down
60 minutes) that causes a
disconnect if TnInActTm is
enabled.
Save
Save
enabled.
Table 5. Alarm Configuration Options
Option
Factory 1
Factory 2
Comments/Description
Alrm Msg:
Disab
Disab
Does not display alarm messages.
Alrm Msg:
Com
Com
Sends alarm messages to COM port.
SNMP Trap:
Enab
Enab
Sends SNMP traps
SNMP Trap:
Disab
Disab
Sends SNMP traps.
TrapDisc:
Enab
Enab
Specifies whether the modem
connection will disconnect after a trap
TrapDisc:
Disab
Disab
p
connection will disconnect after a trap
is sent.
DialOut:
Enab
Enab
Provides the option to allow automatic
dial out to send alarm messages on
DialOut:
Disab
Disab
p
dial-out to send alarm messages on
MODEM port.
Call Retry:
Enab
Enab
Specifies whether an outgoing call is
Call Retry:
Disab
Disab
Specifies whether an outgoing call is
retried on a busy or failed call attempt.
Dial Delay:
1–4
5
6–10
1–4
5
6–10
The time (in minutes) to delay between
successive alarm dial-outs or retry
attempts.
AltDialDir:
None
1–5
None
1–5
The alternate dial-out directory to use if
a call to the primary number cannot be
completed.
Err Rate:
10E–4
10E–4
The error rate threshold for Excessive
Error Rate Alarm
Err Rate:
(Excessive Error Rate)
10E-5–10E-9
10E-5–10E-9
Error Rate Alarm.
AlrmRelay:
Enab
Enab
Specifies whether to activate
AlrmRelay:
(Alarm Relay)
Disab
Disab
Specifies whether to activate
the alarm relay on an alarm condition.