beautypg.com

Installation, Model sg6h fryer – Pitco Frialator Solstice Gas Fryer with Filter SFSG6H User Manual

Page 9

background image

MODEL SG6H FRYER

INSTALLATION

L20-332, rev. 1 (05/11)

5

1.4.3. CE GAS TABLE (NOT APPLICABLE TO ALL MODELS)
Refer to the following table for gas specifications for the country of use. If the country of use is
NOT listed, refer to the information stamped on the data plate.

Country

Fuel

Type

Gas

Ap

p

lian

ce

Category

I

nput (Gross)

kW

I

nput (Net)

kW

S

uppl

y

Pressure

(mbar)

Bu

rn

er

Pressure

(mbar)

Bu

rn

er

O

rifice

Pilo

t O

rifice

(code)

Governor

No

m r

a

te

(m3/hr)

Restrictor

O

rifice

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20/G25

I2E+

36.0

20/25

10

#41/#38

N22

NO

3.8/4.4

5.61 mm

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

N/A

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

LP

G31

I3P

40

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

40

36.0

20

10

#41

N22

YES

3.8

LP

Nat

G20

I2H

40

36.0

20

10

#41

N22

YES

3.8

LP

Nat

G20

I2H

40

36.0

20

10

#41

N22

YES

3.8

LP

Nat

G20/G25

I2Esi

36.0

20/25

10

#41/#38

N22

YES

3.8/4.4

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20/G25

I2ELL

36.0

20/25

10

#41/#38

N22

YES

3.8/4.4

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

LP

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

40

36.0

20

10

#41

N22

YES

3.8

LP

Nat

G20

I2E

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

40

36.0

20

10

#41

N22

YES

3.8

LP

Nat

LP

G31

I3P

40

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G25

I2L

36.0

25

10

#38

N22

YES

4.4

LP

G31

I3P

36.8

50

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

40

36.0

20

10

#41

N22

YES

3.8

LP

Nat

G20

I2E

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

40

36.0

20

10

#41

N22

YES

3.8

LP

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Nat

G20

I2H

36.0

20

10

#41

N22

YES

3.8

LP

G31

I3P

36.8

50/37

25.4

#53

LP16

YES

1.5

Austria (AT)

40

Belgium (BE)

Bulgaria (BG)

Cyprus (CY)

Czech Rep. (CZ)

Denmark (DK)

Estonia (EE)

Finland (FI)

France (FR)

40

40

Iceland (IS)

Ireland (IE)

Italy (IT)

Lithuania (LT)

Germany (DE)

Great Britain (GB)

Greece (GR)

40

T H I S C O U N TR Y D O E S N O T U S E N A T U R A L G A S

NOT APPROVED FOR USE WITH LP GAS IN THIS COUNTRY

N/A

N/A

NOT APPROVED FOR USE WITH LP GAS IN THIS COUNTRY

NOT APPROVED FOR USE WITH LP GAS IN THIS COUNTRY

Turkey (TR)

40

Hungary

40

40

40

40

40

NO DATA AVAILABLE FOR THIS COUNTRY

40

40

NOT APPROVED FOR USE WITH LP GAS IN THIS COUNTRY

Luxembourg (LU)

Latvia (LV)

Switzerland (CH)

NOT APPROVED FOR USE WITH LP GAS IN THIS COUNTRY

40

Romania (RO)

Spain (ES)

Slovakia (SK)

Malta (MT)

Netherlands (NL)

Norway (NO)

Poland (PL)

Slovenia

40

Sweden (SE)

NOT APPROVED FOR USE WITH LP GAS IN THIS COUNTRY

T H I S C O U N TR Y D O E S N O T U S E N A T U R A L G A S

40

40

40

40

Portugal (PT)

NOT APPROVED FOR USE WITH LP GAS IN THIS COUNTRY

40

40

40

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

This manual is related to the following products: