MODEL SG6H FRYER

OPERATION

L20-332, rev. 1 (05/11)

13

2.1.1. BASIC OPERATIONAL FEATURES

1. Cook

Tank

2. Front

Panel

If the appliance is equipped with a
computer or digital controller, it will be
located on the front panel.

3. Door

(Shown Open)

Provides access to,
 the drain valve handle, tank drain

outlet and high temperature reset
button

 Solid State thermostat (if

equipped).

 gas valve, pilot, burners, gas

shutoff valve and self cleaning
burner system (if equipped).

 Filter models: Filter pump,

oil/shortening return handle and
flush hose (if equipped).

4. Drain Valve Handle (Blue) (Shown

in the closed position)

Opens the drain valve so
oil/shortening can be drained from the
cook tank.
If the drain valve interlock feature is
equipped, the appliance will stop
heating if the drain valve is opened.

5. Tank Drain Outlet

Oil/shortening exits the cook tank
through the drain outlet when draining.

6. High Temperature Reset Button

This button may need to be pressed in
the event that the high temperature
limit has tripped.

7. Rack

Lift

Assist

Aids in lifting racks in and out of tank.

8. Gas Valve Knob

The gas valve controls the flow of gas
to the pilot and burners.

Turning the gas valve knob to the OFF
position shuts off the gas supply to the
pilot and burners

9. Pilot

The pilot lights the burners when the
water in the cook tank requires more
heat.

10. Burners

Heats the oil/shortening inside the
cook tank.

11. Self Cleaning Burner System (if

equipped)

The self cleaning burner system
cleans the burners when the
appliance is turned ON.

2.1.2. OPERATION FEATURES SPECIFIC TO MODELS WITH FILTERS.

12. Filter Pump

The filter pump is used to pump
oil/shortening from the filter pan back
into the cook tank or through the flush
hose (if equipped).

13. Filter Pump Reset Button

This button may need to be pressed in
the event that the filter pump circuit
breaker has tripped.

14. Oil Return Handle (Red)

Oil exits the cook tank through the
drain outlet when draining.

15. Filter Pan

Oil drained from the cook tank goes
into the filter pan.

Filter media is located inside the filter
pan.

16. Flush Hose Connection (if

equipped)

Connect the flush hose here when
using the flush hose feature.

17. Flush Hose Handle (Yellow) (if

equipped)

Pulling this handle starts the flow of
oil/shortening through the flush hose.
Pushing the handle in will stop the
flow of oil/shortening through the flush
hose.

18. Waste Oil Management Handle

(Brown) (if equipped)

Directs the oil to a waste oil container.

This manual is related to the following products: