Linesense, Ttx400 – Philips TTX400 User Manual
Page 40
Philips indoor luminaires
8.39
Light-line systems
Light-line systems
Daylight linking Manual override
Movement detection
Switch on/off
or dim to
10, 20, 30%
Switch on/off
Best performance
Best economy
ZTX400 MDU HFD
ZTX400 MDU HFP
Movement detection (detector LRM8117)
Minimum light level without presence
0, 10, 20, or 30%
0
Maximum number of presence detectors per control unit
4
2*
Maximum cable length for movement detector
300 m
125 m
Daylight linking (light sensor LRL8102)
-
Number of light sensors per control unit
1
-
Manual control
(on, off and override)
-
Type of ballast
HFD***
HFP
Maximum number of ballasts per line
64
**
TTX400 system
7 wire
5 wire
Linesense
With Linesense, TTX400 and controls are combined in one. The speed and ease
of installation of TTX400 remains when Linesense is used. In addition, substantial
energy savings up to 75% can be achieved. Linesense has been developed for
industrial applications like warehouses.
Installation clicks only
1 ZTX400 MDU control unit clicks onto the trunking.
2 Movement detector clicks on the bracket.
3 ZTX400 MB-MDU bracket clicks on the trunking.
4 Telejack cables click the detector and control unit together.
5 ZTX400 CU mains connection clicks on the control unit.
ZTX400 MDU
Pre-wired Linesense unit
with integrated control
function
ZTX400 MB-MDU
Mounting bracket for
movement detector
LRM8117/00
LRM8117/00
High-bay passive infrared
movement detector
Mounting height up to
15 m
TTX400
Linesense consists of a 618 mm piece
of trunking, which is fully pre-equipped
and wired to be added to the trunking.
The control function is integrated into
this extra unit, and can easily be clicked
between the light line and the electrical
connection unit. High bay movement
detectors are connected with standard
RJ-12 cables and mounted at the right
location with the use of dedicated
brackets. Linesense is equipped as
standard with a telejack splitter to
easily connect the detectors to the
light line.
* 2 presence detectors or 3 with LED disabled
** any number of luminaires allowed by the TTX400 light line system
*** HFD=HFR-DALI
TTX
400
TTX
400