8.20

Maxos

Light-line systems

Maxos electrical units
The electrical units for Maxos trunking sections can hold 1 or 2
TL5 or TL-D lamps and are designed for quick and reliable click-in
mounting. They are made of steel with a white or silver coating.

The electrical units can be equipped with HFP electronic ballasts, HFR
dimming ballasts (allowing light output of a TLD-lamp to be regulated
from 3 to 100%), HF-DALI ballasts or low-loss conventional ballasts.
HFR and HF-DALI units must be mounted to 7-wire trunking sections.
The conventional ballasts are available parallel compensated (IC) or
inductive (I).

Special electrical units equipped with an emergency battery pack for
1 or 3 hours (EL1/EL3) are available. These units must be used with
7-wire trunking sections. If trunkings with double wiring are used, one
flat ribbon cable will be connected to the central battery. This provides
a completely separate emergency lighting circuit.

Some 2-lamp TL-D reflectors need dedicated electrical units (F32)
with a short distance between the lamps. On request, the TL-D
electrical units can be upgraded from IP20 to IP40 with an IP40 set
that is available as an accessory.

Maxos TL5
Electrical units

Type

4MX691

Lamp

Fluorescent:
1 x or 2 x MASTER TL5 / G5 / 35, 54, 49, 80 W

Gear

Electronic, 220 - 240 V / 50 - 60 Hz:
High Frequency Performer (HFP)
High Frequency Regulator (HFR)
High Frequency Regulator, DALI (HFD)

Option

Emergency lighting:
1 hour (EL1)
3 hours (EL3)

Material

Sheet steel in white (WH) or silver (SI)

Installation

Click-in fixation (mechanical and electrical) on
trunking

Maxos TL-D
Electrical units

Type

4MX091

Lamp

Fluorescent:
1 x or 2 x MASTER TL-D / G13 / 36, 58 W

Gear

Electro magnetic (low loss), 230 or 240 V / 50 Hz:
Inductive, parallel compensated (IC)
Electronic, 220 - 240 V / 50 - 60 Hz:
High Frequency Performer (HFP)
High Frequency Regulator (HFR)
High Frequency Basic (HF-Dali)

Option

Emergency lighting:
1 hour (EL1), 3 hours (EL3)
2-lamp lampholder of 32 mm (F32) to be used in
facetted and aluminum reflectors, standard is 115
mm
Master/slave unit: pair of electrical units one with
gear (M) one without gear (S)

Material

Sheet steel in white (WH) or silver (SI)

Installation

Click-in fixation (mechanical and electrical) on
trunking

Remarks

Dedicated IP40 sets for upgrading from IP20 to
IP40

Where relevant, for detailed descriptions of Lighting Controls we refer you to chapter 11, and descriptions for e.g. optics/optical covers, lamps data, photometrical diagrams, etc. to the respective sections in chapter 12.

Indoor_2008_Chapter_08_LIS.indb 20

20-05-2008 13:22:52