Polycom Ceiling DocCam User Manual
Page 15
Ceiling DocCam II — Appendix
27
Ceiling DocCam II — Appendix
26
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Command Set
Command
Command Packet
Comments
CAM_KeyLock
Off
81 01 04 17 00 FF
On
81 01 04 17 02 FF
Line Lock
INT
81 01 04 22 0p 0q 0r 0s FF
pqrs: Camera ID
(=0000 to FFFF)
81 01 04 55 00 FF
81 01 04 55 01 FF
Camera Control
Enable/Disbale
CAM_IDWrite
CAM_ExternalLock
Internal Mode
Line Lock mode
pp pp pp pp: Mask
Color Settings
qq: Color Setting when
0 is selected
rr: Color SEtting when
1 is selected
mm: Mask Settings
nn 00: Modify, 01: New
pp: X, qq: Y, rr: W, ss: H
SetMask
Display
SetMask Color
SetPan TiltAngle
81 01 04 76 mm nn
0p 0p 0q oq 0r 0r 0s 0s FF
81 01 04 77 pp pp pp pp FF
81 01 04 78 pp pp pp pp
qq rr FF
81 01 04 79 0p 0p 0p
0q 0q 0q FF
Move Pan Tilt
81 01 04 7A 0p 0p 0q 0q rs FF
Pan/Tilt Angle Settings
ppp: Pan
qqq: Tilt
CAM_PrivacyZone
Mask Display On/Off
pp pp pp pp : Mask
Settings (0: Off, 1: On)
pp: Pan Speed
qq: Tilt Speed
r 0: Stop, 1: Right,
2: Le ft
s 0: Stop, 1: Up,
2: Down
Set PTzMask
81 01 04 7B mm 0p 0p 0p
0q 0q 0q 0r 0r 0r FF
Pan/Tilt/Zoom Settings
for Mask
ppp:Pan, qqq: tilt
rrr: zoom
GridOn
81 01 04 7C 02 FF
Grid Display On/Off
GridOff
81 01 04 7C 03 FF
CAM_Alarm
On
81 01 04 6B 02 FF
Off
81 01 04 6B 03 FF
SetMode
Alarm (Reply)
SetTime
81 01 04 6C pp FF
PP: Mode Settings
00 Focus Move Detection
(The rest position is fixed.)
01 Focus Move Detection
(The rest position is reset.)
02 AE Move Detection
(The rest value is fixed.)
01 AE Move Detection
(The rest value is reset.)
81 01 04 6D 0p 0p FF
90 07 04 6B 01 FF
81 01 04 55 00 FF
Alarm On/Off
pp: Reset Time Setting
Detect Level
"Low" to "High"
90 07 04 6B 00 FF
Detect Level
"High" to "Low"
CAM_ExternalLock INT
LIne Lock
81 01 04 55 01 FF
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Command Set
Command
Command Packet
Comments
On
Off
81 01 04 34 02 FF
81 01 04 34 03 FF
CAM_Stablizer
Reset
Set
81 01 04 3F 00 0p FF
Vibration Correction
On/Off
81 01 04 3F 01 0p FF
CAM_Memory
p: Memory Number
(=0 to 5)
Recall
81 01 03 3F 01 0p FF
CAM_Custom
Reset
81 01 04 3F 00 7F FF
Set
81 01 04 3F 01 7F FF
mm: Vposition,
nn: Hposition, pp: Color
qq: Blink
Display On/Off
On
Off
On/Off
Title Set 1
Title Set 3
81 01 04 15 02 FF
(81 01 06 06 02 FF)
81 01 04 15 03 FF
(81 01 06 06 03 FF)
81 01 04 15 10 FF
(81 01 04 06 06 10 FF)
81 01 04 73 00 mm nn pp
qq 00 00 00 00 00 00 FF
81 01 04 73 01 mm nn pp
81 01 04 73 02 mm nn pp
qq rr ss tt uu vv ww FF
Starts in this mode at
Power on
CAM_Title
Title Clear
On
81 01 04 74 00FF
mnpqrstuvw: Setting of
Display Characters
11st to 20 th Character
81 01 04 74 02 FF
Recall
81 01 04 3F 02 7F FF
Title Set 2
qq rr ss tt uu vv ww FF
mnpqrstuvw: Setting of
Display Characters
1st to 10th Character
Title Setting Clear
Off
81 01 04 74 03 FF
CAM_Display
Title Display On/Off
On
81 01 04 75 02 FF
Off
81 01 04 75 03 FF
Mute On/Off
ON/Off
81 01 04 75 10 FF
CAM_Mute
Phase Turnover
Stop
Down
Up (Step)
Up
Down (Step)
Reset
Direct
81 01 04 05 02 FF
81 01 04 05 03 FF
81 01 04 08 2p FF
81 01 04 05 3p FF
81 01 04 05 40 FF
81 01 04 45 00 00 0p 0q FF
0 degree
180 degree
81 01 04 25 00 FF
Restore factory settings
81 01 04 25 01 FF
CAM_VPhase
81 01 04 05 00 FF
p=step (1-7)
pq: V-Phase (00-FF)
No Phase Turnover