beautypg.com

Glossary duty cycle, Specifications, Accessories – PYLE Audio C6110 User Manual

Page 8

background image

8- ENG

A10244

GLOSSARY

DUTY CYCLE

This air compressor pump is capable of running continuously. However, to

prolong the life of your air compressor, it is recommended that a 50%-75%

average duty cycle be maintained; that is, the air compressor pump should not

run more than 30-45 minutes in any given hour.

Become familiar with these terms before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure of air delivery.
PSIG: Pounds per square inch gauge; a unit of measure of pressure.
Code Certification: Products that bear one or more of the following marks: UL,

CUL, ETL, CETL, have been evaluated by OSHA certified independent safety

laboratories and meet the applicable Underwriters Laboratories Standards for

Safety.
Cut-In Pressure: While the motor is off, air tank pressure drops as you

continue to use your accessory. When the tank pressure drops to a certain low

level the motor will restart automatically. The low pressure at which the motor

automatically restarts is called "cut-in" pressure.
Cut-Out Pressure: When an air compressor is turned on and begins to run,

air pressure in the air tank begins to build. It builds to a certain high pressure

before the motor automatically shuts off - protecting your air tank from

pressure higher than its capacity. The high pressure at which the motor shuts

off is called "cut-out" pressure.
Branch Circuit: Circuit carrying electricity from electrical panel to outlet.

SPECIFICATIONS

Accessories for this unit are available at the store the unit was purchased.

ACCESSORIES

Model Nos.

C6110

Running Horsepower

1,9

Bore

2-3/8"

Stroke

1.35"

Voltage/Hz-Single Phase

60/120

Minimum Branch Circuit Requirement

15 amps

Fuse Type

Time Delay

Air Tank Capacity (Gallon)

25

Approximate Cut-in Pressure

120 PSIG

Approximate Cut-out Pressure

150 PSIG

SCFM @ 40 PSIG

7.7

SCFM @ 90 PSIG

5.4