SERVICE AND ADJUSTMENTS

To Replace or Clean Check Valve

1. Release all air pressure from air tank. See "To Drain Tank" in the

"Maintenance" section.

2. Set the On/Auto/Off lever to "Off" and unplug unit.
3. Using an adjustable wrench loosen outlet

tube nut at air tank and pump. Carefully

move outlet tube up away from check

valve.

4. Using an adjustable wrench loosen

pressure relief tube nut at air tank and

pressure switch. Carefully move pressure

relief tube away from check valve.

5. Unscrew the check valve (turn

counterclockwise) using a 7/8" open

end wrench.

Note the orientation for

reassembly.

6. Using a screwdriver, carefully push

the valve disc up and down.

NOTE:

The valve disc should move freely

up and down on a spring which

holds the valve disc in the closed

position, if not the check valve

needs to be cleaned or replaced.

7. Clean or replace the check valve.

A solvent, such as paint or varnish

remover can be used to clean the

check valve.

8. Apply sealant to the check valve threads. Reinstall the check valve (turn

clockwise).

9. Replace the pressure release tube. Tighten nuts.
10. Replace the outlet tube and tighten nuts.
11. Replace shrouds.
12. Perform the Break-in Procedure. See "Break-in Procedure" in the

"Operation" section.

Outlet Tube

In closed position

disc is visible.

In open

position

nothing is

visible.

Screwdriver

Risk of Unsafe Operation. Unit cycles automatically when

power is on. When servicing, you may be exposed to

voltage sources, compressed air, or moving parts. Before servicing unit

unplug or disconnect electrical supply to the air compressor, bleed tank of

pressure, and allow the air compressor to cool.

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE
PERFORMED BY TRAINED SERVICE TECHNICIAN.