To Drain Tank

1. Set the On/Auto/Off lever to "Off" and unplug unit.
2. Pull the regulator knob out and turn counterclockwise to set the outlet

pressure to zero.

3. Remove the air tool or accessory.
4. Pull ring on safety valve allowing air to bleed from the tank until tank

pressure is approximately 20 psi. Release safety valve ring.

5. Drain water from air tank by opening drain valve (counter-clockwise) on

bottom of tank.

Risk of Bursting. Water will condense in the air tank. If
not drained, water will corrode and weaken the air tank

causing a risk of air tank rupture.
6. After the water has been drained, close the drain valve (clockwise). The air

compressor can now be stored.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be
removed, cleaned, the reinstalled.

To Check Safety Valve

Risk of Bursting. If the safety valve does not work

properly, over-pressurization may occur, causing air tank

rupture or an explosion.
1. Before starting compressor, pull the ring on the safety valve to make

sure that the safety valve operates freely. If the valve is stuck or does not

operate smoothly, it must be replaced with the same type of valve.

Air Filter Inspection and Replacement

Hot surfaces. Risk of burn. Compressor heads are

exposed when filter cover is removed. Allow compressor

to cool prior to servicing.

Keep the air filter clean at all times. Do not operate the air

compressor with the air filter removed.

A dirty air filter will not allow the compressor pump to operate at full capacity.

Before you use the compressor pump, check the air filter to be sure it is clean

and in place.
If it is dirty, replace it with a new filter. On some models, the filter may be

removed by using a pair of needle nose pliers or a screwdriver. Pull or pry out

the old filter and carefully clean the filter area. Push in the new air filter.

Air Compressor Pump Intake and Exhaust Valves

Once a year have a Trained Service Technician check the air compressor pump

intake and exhaust valves.