Description of Operation

Become familiar with these controls before operating the unit.
On/Auto/Off Switch: Turn this switch

"On/Auto" to provide automatic

power to the pressure switch and

"Off" to remove power at the end of

each use.
Pressure Switch: The pressure

switch automatically starts the

motor when the air tank pressure

drops below the factory set "cut-in"

pressure. It stops the motor when the

air tank pressure reaches the factory

set "cut-out" pressure.
Safety Valve: If the pressure switch

does not shut off the air compressor

at its "cut-out" pressure setting, the

safety valve will protect against high

pressure by "popping out" at its factory set pressure (slightly higher than the

pressure switch "cut-out" setting).

Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure

available at the outlet side of the regulator. This pressure is controlled by the

regulator and is always less than or equal to the tank pressure.
Tank Pressure Gauge: The tank pressure gauge indicates the reserve air

pressure in the tank.
Regulator: Controls the air pressure shown on the outlet pressure gauge. Pull

the knob out and turn clockwise to increase pressure and counterclockwise to

decrease pressure. When the desired pressure is reached push knob in to lock

in place.
Universal Quick-Connect Body: The universal quick-connect body accepts

the three most popular styles of quick-connect plugs: Industrial, automotive

(Tru-flate), and ARO. One hand push-to-connect operation makes connections

simple and easy.
Drain Valve: The drain valve is located at the base of the

air tank and is used to drain condensation at the end of

each use.
Cooling System (not shown): This compressor contains

an advanced design cooling system. At the heart of this

cooling system is an engineered fan. It is perfectly normal

for this fan to blow air through the vent holes in large amounts. You know that

the cooling system is working when air is being expelled.

OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING

YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with

the location of various controls and adjustments. Save this manual for future

reference.

Safety

Valve

Regulator

Outlet

Pressure

Gauge

On/Auto/Off

Switch

Pressure
Switch

Tank

Pressure

Gauge

Universal

Quick-

Connect

Body

Drain

Valve