Air Compressor Pump (not shown): Compresses air into the air tank.
Working air is not available until the compressor has raised the air tank
pressure above that required at the air outlet.
Check Valve: When the air compressor is operating,
the check valve is "open", allowing compressed air to
enter the air tank. When the air compressor reaches
"cut-out" pressure, the check valve "closes", allowing
air pressure to remain inside the air tank.
Pressure Release Valve: The pressure release valve
located on the side of the pressure switch, is designed
to automatically release compressed air from the
compressor head and the outlet tube when the air
compressor reaches "cut-out" pressure or is shut off.
The pressure release valve allows the motor to restart
freely. When the motor stops running, air will be heard
escaping from this valve for a few seconds. No air
should be heard leaking when the motor is running or
after the unit reaches "cut-out" pressure.
Motor Overload Protector: The motor has an
automatic reset thermal overload protector. If the motor
overheats for any reason, the overload protector will
shut off the motor. The motor must be allowed to cool down before restarting.
The compressor will automatically restart after the motor cools.
How to Use Your Unit
How to Stop:
1. Set the On/Auto/Off lever to "Off".
Before Starting
Break-in Procedure
Risk of Unsafe Operation. Serious damage may result if
the following break-in instructions are not
closely followed.
This procedure is required
before the air compressor is put into service and
when the check valve or a complete compressor pump has been replaced.
1. Make sure the On/Auto/Off lever is in the "Off" position.
NOTE: Pull coupler back until it clicks to prevent air from escaping through the
quick connect.
2. Plug the power cord into the correct branch circuit receptacle. (Refer to
Voltage and Circuit Protection paragraph in the Installation section of this
manual.)
3. Open the drain valve (counter-clockwise) fully to permit air to escape and
prevent air pressure build up in the air tank during the break-in period.
4. Move the On/Auto/Off lever to "On/Auto" position. The compressor will start.
5. Run the compressor for 15 minutes. Make sure the drain valve is open and
there is minimal air pressure build-up in tank.
6. After 15 minutes, close the drain valve by turning clockwise. The air
receiver will fill to "cut-out" pressure and the motor will stop.
The compressor is now ready for use.
Check Valve
Pressure Release Valve