beautypg.com

How to use your unit – PYLE Audio C6110 User Manual

Page 12

background image

12- ENG

A10244

Air Compressor Pump (not shown): Compresses air into the air tank.

Working air is not available until the compressor has raised the air tank

pressure above that required at the air outlet.
Check Valve: When the air compressor is operating,

the check valve is "open", allowing compressed air to

enter the air tank. When the air compressor reaches

"cut-out" pressure, the check valve "closes", allowing

air pressure to remain inside the air tank.
Pressure Release Valve: The pressure release valve

located on the side of the pressure switch, is designed

to automatically release compressed air from the

compressor head and the outlet tube when the air

compressor reaches "cut-out" pressure or is shut off.

The pressure release valve allows the motor to restart

freely. When the motor stops running, air will be heard

escaping from this valve for a few seconds. No air

should be heard leaking when the motor is running or

after the unit reaches "cut-out" pressure.
Motor Overload Protector: The motor has an

automatic reset thermal overload protector. If the motor

overheats for any reason, the overload protector will

shut off the motor. The motor must be allowed to cool down before restarting.

The compressor will automatically restart after the motor cools.

How to Use Your Unit

How to Stop:
1. Set the On/Auto/Off lever to "Off".

Before Starting

Break-in Procedure

Risk of Unsafe Operation. Serious damage may result if

the following break-in instructions are not

closely followed.
This procedure is required

before the air compressor is put into service and

when the check valve or a complete compressor pump has been replaced.
1. Make sure the On/Auto/Off lever is in the "Off" position.
NOTE: Pull coupler back until it clicks to prevent air from escaping through the

quick connect.
2. Plug the power cord into the correct branch circuit receptacle. (Refer to

Voltage and Circuit Protection paragraph in the Installation section of this

manual.)

3. Open the drain valve (counter-clockwise) fully to permit air to escape and

prevent air pressure build up in the air tank during the break-in period.

4. Move the On/Auto/Off lever to "On/Auto" position. The compressor will start.
5. Run the compressor for 15 minutes. Make sure the drain valve is open and

there is minimal air pressure build-up in tank.

6. After 15 minutes, close the drain valve by turning clockwise. The air

receiver will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

Check Valve

Pressure Release Valve