The following is the summary table of Reset button functions
:
Reset Button Pressed and Released
Function
About 1 second
Reboot the PoE Injector Hub
Until the SYS LED lit off
Reset the PoE Injector Hub to Factory Default configuration.
The PoE Injector Hub will reboot and load the default IP
settings as below:
。
Default Password: admin
。
Default IP address: 192.168.0.100
。
Subnet mask: 255.255.255.0
。
Default Gateway: 192.168.0.254
To press the RESET button about 10 seconds and then release. The PoE Injector Hub will back
to the factory default mode. Be sure that you backup the current configuration of PoE Injector
Hub; else the entire configuration will be erased when pressing the “RESET” button.
2.1.2 LED Indicators
The front panel LEDs indicates instant status of system power, Management port Link/Active and PoE port links, helps
monitor and troubleshoot when needed.
LED
Color
Function
POWER
Green
Lights to indicate power on.
Amber
Lights to indicate the port is running in 100Mbps speed
Blink: indicate that the PoE Injector Hub is actively sending or receiving data over
that port.
Manage
Green
Lights to indicate the port is running in 10Mbps speed
Blink: indicate that the PoE Injector Hub is actively sending or receiving data over
that port
PoE In-use
Green
Lights to indicate that the port is in use and supplying 48V DC power
2.1.3 Injector Rear Panel
The rear panel of the PoE Injector Hub indicates an AC inlet power socket, which accepts input power from 100 to 240V
AC, 50/60Hz.