Transmission / Receiving Protocol

Transmission

[F6][Command][SetID][Data][CS][6F]
* [F6] : Start of Communication
* [Command] : Command set
* [Set ID] : You can adjust the set ID to choose desired
monitor ID number in SETUP menu. See previous page.
Adjustment range is 1~99.
* [DATA] : To transmit command data. Transmit ‘FF’ data to
read status of command.
* [Cr] : Check Sum ASCII code ‘0x0D’
* [6F] : End of Communication

OK Acknowledgement

[F7][Command][SetID][Data][CS][7F]

* The Monitor transmits
ACK(acknowledgement) based on this format
when receiving normal data. At this time, if the
data is data read mode, it indicates present
status data. If the data is data write mode, it
returns the data of the PC computer.

Error Acknowledgment

[F7][Command][SetID][FF][CS][7F]

* The Monitor transmits
ACK(acknowledgement) based on this format
when receiving abnormal data from non-viable
function or communication errors.

01. Power

: To control Power On/Off of the set

Transmission
[F6][01][SetID][Data][CS][6F]
Data 0 : Power Off 1 : Power On

OK Acknowledgement
[F7][01][SetID][Data][CS][7F]

: To show Power On/Off

Transmission
[F6][01][SetID][FF][CS][6F]

OK Acknowledgement
[F7][01][SetID][Data][CS][7F]Data 0 : Off 1 : On

* In like manner, if other functions transmit ‘FF’ data based
on this format, Acknowledgement data feed back presents
status about each function.

02. Volume Mute

: To control volume mute On/Off of the set

Transmission
[F6][02][SetID][Data][CS][6F]
Data 0 : Volume Mute Off (Volume On)
1 : Volume Mute On (Volume Off)

OK Acknowledgement
[F7][02][SetID][Data][CS][7F]

03. Screen Mute

: To select screen mute On/Off

Transmission
[F6][03][SetID][Data][CS][6F]

Data 0 : Screen Mute Off (Picture On)
1 : Screen Mute On (Picture Off)

OK Acknowledgement
[F7][03][SetID][Data][CS][7F]

04. Contrast

: To adjust screen contrast. You can also adjust contrast in
the PICTURE menu.

Transmission
[F6][04][SetID][Data][CS][6F]
Data Min : 0 ~ Max : 64

* Refer to ‘Real data mapping1’.

OK Acknowledgement
[F7][04][SetID][Data][CS][7F]