Item
600
INPUT C
0000
B/W
KILL
0001
AUTO
™ ™
601
OUT
0000
N-VF
VSYNC
0001
VF
™
602
V-MUTE
0000
N-MUTE
SEL
0001
LOW_RF
™ ™
603
CC (F1)
0000
BLANK
BLANK
0001
THRU
™ ™
604
CC (F2)
0000
BLANK
BLANK
0001
THRU
™ ™
605
FREEZE
0000
FIELD
SEL
0001
FRAME
™ ™
606
IN FRM
0000
FORCE
DET
0001
AUTO
™ ™
607
VIN SETUP
0000
THRU
0001
CUT
™ ™
608
VOUT SETUP
0000
THRU
0001
ADD
™ ™
The underlined number and item are the factory settings.
DETAILED DESCRIPTION OF SET-UP MENUS
32
This selects the color killer processing for the video input signals.
0: B/W processing is conducted forcibly.
1: Automatic processing is conducted.
This selects whether the internal sync signal is to be floated so that H is
aligned with the video output signal and V is aligned with the video input sig-
nal during EE.
0: Internal sync signal is not floated.
1: Internal sync signal is floated.
This selects where the video signals are to be muted during playback under
low RF conditions or when the servo lock is disengaged.
0: Signals are not muted.
1: Signals are muted.
This selects ON or OFF for the closed caption signal in the first field.
0: Signal is forcibly blanked.
1: Signal is not blanked.
This selects ON or OFF for the closed caption signal in the second field.
0: Signal is forcibly blanked.
1: Signal is not blanked.
This selects freeze for the still picture either during play or when operation is
transferred from play to stop.
0: Field freeze
1: Frame freeze
(Field freeze is set at all times when the laptop is in a mode other than the
one mentioned above.)
This selects frame detection for the input signals.
0: Frame detection is conducted at all times.
1: Frame detection is prohibited only with NON-STD signals.
This selects the 7.5% setup processing for the input composite signal.
0: The signal is recorded in its original form.
1: The signal is recorded with the 7.5% setup removed.
This selects the 7.5% setup processing for the output composite signal.
0: The signal is output in its original form.
1: The signal is output with the 7.5% setup added.
V
V
T
T
R
R
1
2