Panasonic WV-CL924A User Manual
Page 31
-32-
2. After confirming the cursor is on LL, press
. The
vertical phase adjustment menu appears on the
monitor.
3. Supply the video output signal of the camera to be
adjusted and the reference camera video output
signal to a dual-trace oscilloscope.
4. Set the oscilloscope to the vertical rate and expand
the vertical sync portion on the oscilloscope.
5. Move the cursor to COARSE. The cursor starts
blinking.
6. Press
or
to match the vertical phase for
both video output signals as closely as possible.
(COARSE adjustment can be incremented in 16
steps by 22.5 degrees by pressing
or
.)
Note:
After the sixteenth step, the adjustment
returns to the first step.
7. Move the cursor to FINE.
8. Press
or
to match the vertical phase for
both video output signals as closely as possible.
(FINE adjustment can be made up to 22.5 degrees
by pressing
or
.)
Notes:
• When the “I” cursor reaches the “+” end, it
jumps back to “
−
”. At the same time, COARSE
is incremented by one step to enable a contin-
uous adjustment. The reverse takes place
when the “I” cursor reaches the “
−
” end.
• When
or
is kept pressed for a second
or more, the “I” cursor moves faster.
1 (1 - - - 16): 0 degrees
2 (1 - - - 16): 22.5 degrees
16 (1 - - - 16): 337.5 degrees
** SYNC **
V PHASE
COARSE 1(1--16)
FINE I........
- +
RET END