beautypg.com

Patton electronic 3040/V35 User Manual

Page 10

background image

3040/V35

139001UA

2-2

I

NSTALLATION

A

ND

O

PERATIONS

M

ANUAL

S

ETUP

& I

NSTALLATION

P

ATTON

E

LECTRONICS

C

O

.

Switch 18 - 1, 2, 3, 7 and 8 to

OFF

OFF

OFF

OFF

OFF

, 4, 5 and 6 to

ON

ON

ON

ON

ON

Anti-Stream timer = 2 M bits
Anti-Stream = Disabled
Broadcast Data to Sub-Channels
RX Clock Source = Master

JP4 Thru JP7

Open

Open

Open

Open

Open

HS Option Not Enabled

JP8 thru JP12 to

Open

Open

Open

Open

Open

DTR / DSR Not Forced

JP1 Thru JP3 to

Installed

Installed

Installed

Installed

Installed

Factory Test Jumpers

If the system application requires one or more of the default settings to be changed, it will be
necessary to remove the top cover of the enclosure to access and change the DIP switches
located on the printed circuit board.

Disassembly

Remove the top cover by removing the phillips head screws located on the left and right sides
of the 3040/V35 (CTS MD-V.35/TCB). DTE/DCE switches SW5 through SW14, baud rate
Jumpers JP4 through JP7, interface Jumpers JP8 through JP12 and configuration switches
SW15 through SW18 are located on the PCB as indicated on the strapping guide in the
Appendix of this manual. After the switch selection activity is completed,

re-install the top

cover BEFORE connecting to a AC power source

.

Installation

Select an appropriate location accessible to and within six feet of an AC power outlet, the
outlet must have a ground pin receptacle for product warranty. The DCE-to-DTE cabling
between each attached device and the 3040/V35 (CTS MD-V.35/TCB) should be “Straight
Through”, shielded and terminated with male connectors. Sub-Channels are marked PORT 1
through PORT 4, the Master Port is marked, MASTER DCE/DTE. If any terminal has a priority
service mode, ensure it is connected to the port connector designated “PORT 1” on the rear
panel of the 3040/V35 (CTS MD-V.35/TCB). Secure other terminals or Modems to be
serviced to the remaining “PORT” connectors. Connect the MODEM or TERMINAL to the
connector designated “MASTER DTE/DCE”.