beautypg.com

Patton electronic ENVIRONETTM 2100 User Manual

Page 29

background image

EnviroNET Model 2168

29

EnviroNET User Manual

3 • Configuring the EnviroNET

Switch 1: Ethernet Auto Sense
To configure the unit for full auto sense capability or limited auto sense capability, push the first toggle switch
up or down. Full Auto sense capability consists of standard Ethernet Auto sensing (100BaseT full duplex,
100BaseT half duplex, 10BaseT full duplex, and 10BaseT half duplex). Limited Auto sensing capability con-
sists on only auto sensing for 100BaseT half duplex, 10BaseT full duplex, and 10BaseT half duplex. The lim-
ited auto negotiation feature is used when an Ethernet device does not comply with IEEE 802.3x (back
pressure flow control) at 100M full duplex

.

Refer to

table 11

for settings.

Switches 2, 3, and 4: Data Rate
Refer to

table 12

for the symmetric line rate settings. (Switch 1 must be in the “On” position).

Refer to

table 13

for the asymmetric line rate settings.(Switch 1 must be in the “Off” position).

Table 11. Ethernet Auto Sense Selection Chart

S1-1

Setting

OFF

Full Auto Negotiation (Factory Default)
(100 Mbps, Full or Half Duplex)
(10 Mbps, Full or Half Duplex)

ON

Limited Auto Negotiation
(100 Mbps Half Duplex)
10 Mbps Full or Half Duplex)

Table 12. Symmetric CopperLink Line Rates Selection Chart

S1-2

S1-3

S1-4

Symmetric Line Rate

ON

ON

ON

6.25 Mbps

ON

ON

OFF

9.38 Mbps

ON

OFF

OFF

12.5 Mbps (Factory Default)

ON

OFF

ON

16.67 Mbps

Table 13. Asymmetric CopperLink Line Rates Selection Chart

S1-2

S1-3

S1-4

Asymmetric Line Rates DS/US

OFF

OFF

ON

4.17 Mbps/1.56 Mbps (Mode 0)

OFF

ON

ON

9.38 Mbps/1.56 Mbps

OFF

ON

OFF

16.67 Mbps/2.34 Mbps