3 • Configuring the EnviroNET
Switch 7: Ethernet Shutdown
To enable or disable Ethernet Shutdown, push toggle switch seven (7) up or down.
Refer to
table 8
for settings
.
Switch 8: Remote Configuration
To enable or disable Remote Configuration, push toggle switch eight (8) up or down.
Refer to
table 9
for settings
.
Note
The S2-8 switch applies to the remote unit only. If enabled, the
remote unit will follow the dip switch configuration of the local unit.
If disabled, the remote unit will use its own dip switch setting to
determine its Ethernet operating mode and Ethernet Shutdown
mode configuration. The S2-8 switch does not affect the data rate.
The data rate will always follow the local configuration.
Table 8. Ethernet Shutdown
S2-7
Description
ON
Ethernet Shutdown Enabled
OFF
Ethernet Shutdown Disabled
Table 9. Remote Configuration
S2-8
Description
ON
Remote Configuration Enabled
OFF
Remote Configuration Disabled