beautypg.com

Wiring the power – Patton electronic ENVIRONETTM 2100 User Manual

Page 17

background image

Wiring the power

17

EnviroNET User Manual

2 • Installing the EnviroNET

Wiring the power

Inside the EnviroNET, the power cable is wired to the power supply, but it is not wired externally because dif-
ferent customers require different lengths of power cable for their specific EnviroNET environments. You will
need to provide your desired length of power cable for the unit.

You should run the power cable through the brass gland that is placed to the far left on the bottom panel of the
EnviroNET. (See

figure 5

). The steps to wiring the power include: running the power cable wires through the

gland, and connecting the power cable wires to the EnviroNET unit.

Running the power cable through the gland

To run the power cable through the gland:

1. Locate the gland that the power cable should be run through. (See

figure 5

).

Figure 5. Gland designated for the power cable

2. You may unscrew the gland to allow more flexibility when threading the power cable wires. To unscrew the

gland, either by hand or with a Crescent® (adjustable) wrench, turn the gland to the left until it is loos-
ened.

3. Carefully thread the wires through the gland from the outside into the EnviroNET.

Note

The brass glands on the bottom panel of the EnviroNET can prop-
erly seal cables with an outer diameter between 3mm and 8mm.

Power cable

gland