Wiring the terminal block

20

EnviroNET User Manual

2 • Installing the EnviroNET

Connecting the twisted pair wires to the EnviroNET

To connect the twisted pair wires to the EnviroNET:

1. Run the twisted pair wires from outside of the EnviroNET through the unscrewed glands (on the right) to

the inside of the unit.

2. Connect the appropriate wires to the appropriate slots in the terminal block. There should be one wire per

gland. Follow the wiring diagram that is on the inside of the EnviroNET door (see

figure 8

).

Figure 8. Terminal block diagram (Displayed on the inside of the EnviroNET door)

3. Be sure to leave a little slack on the wires so that they are not stressed or pulled too tightly. Also, make sure

that the twisted pair wires are secured tightly in the terminal block.

4. To ensure that the cables are properly secured in the gland, tighten the gland by turning the loose pieces all

the way to the right using a Crescent® (adjustable) wrench.

Note

The black plugs for the brass glands on the bottom panel of the
EnviroNET should not be removed.