beautypg.com

Pella CLAD HINGED PATIO DOOR (INCLUDES STANDARD User Manual

Page 12

background image

5F

EXTERIOR

INTERIOR

Drill 1/8” diameter pilot

holes through the clearance

hole in the frame.

5C

Out-Swing

#10 x 3-1/2"

corrosion resistant wood screw

5D

EXTERIOR

INTERIOR

5G

5E

5D

SILL

HEAD

D.

Secure the jambs and head of the door.

Drive #10 x 3-1/2” corrosion resistant

wood screws through the door frame and

shim, into the rough framing. Drive the

screws until snug but DO NOT over-

tighten the screws. DO NOT bend or

bow the unit frame.

E. Drill 13/64” clearance holes through the threshold

but not into the rough opening, at the locations shown

in illustration on previous page (5E & 5G). Install #

10 x 3/1-2” corrosion resistant wood screws through

the threshold into the floor. For Masonry applications

use masonry screws that are a minimum size of 3/16”

diameter x 3” and pilot drill per screw manufacturers’s

recommendations.
NOTE: Not required on In-swing Fixed doors.

Installation clip method:
F. Fasten the door to the opening by

driving two #8 x 1-1/4” corrosion

resistant screws into the pre-punched

holes in the clips. If the clips are bent

and fastened to the interior stud/

block, install the screws as close to

the bend as possible.
Note: DO NOT shim above

the door. For masonry openings

use two masonry screws that

are a minimum size of 3/16”

x 1-1/2” per clip. Pre-drill the

masonry per screw manufacturer’s

recommendations before attempting

to drive the screws in.

PERFORMANCE UPGRADE & HURRICANESHIELD DOORS

PERFORMANCE UPGRADE

Frame Screw and Installation clip methods:
G.

Drive #10 x 3-1/2” corrosion resistant wood screws

through the holes in the threshold

into the floor.

Note: For concrete floors, use masonry screws that are a minimum size of 3/16”

diameter x 3”.